Stainless Steel 1:5 Increasing Push Button Fiber Optical Low Speed Contra Angle Handpiece
Stainless steel 1:5 increasing push button fiber optical contra angle low speed handpiece supporting efficient drilling and shaping in restorative work.Its push button allows for easy and quick connection to dental turbines.
The fiber optical illumination ensures clear visibility in the oral cavity, enhancing procedural accuracy. With a slim,ergonomic design, it reduces hand fatigue during use. Its stainless steel construction ensures durability and reliability.
The handpiece is autoclavable for easy sterilization, ensuring safety and hygiene in clinical settings. Its compact size and lightweight nature make it suitable for various dental procedures, including cavity preparation and tooth polishing, offering the benefits of increased speed and torque for optimal clinical outcomes.
Ratio | 1:5 |
Air pressure | 0.25–0.30 Mpa |
Chuck type | Push button |
Spray | 4 Water spray |
Max. speed | 200,000 rpm |
Noise | ≤65 dB |
Handpiece body, key for back cap, oil cleaning nozzle
Preparation:
Ensure that the handpiece has been adequately sterilized using an autoclave prior to each use. Verify that the bur is compatible with the handpiece and is securely attached.
Connection:
Attach the handpiece to the dental unit with the correct coupling. Make sure the connection is secure and tight to avoid any air or water leaks.
Power Supply:
Connect the handpiece to the electric power source according to the specifications of the dental unit.
Check that the power supply falls within the recommended range for the handpiece.
Inserting the Bur:
Press the bur release button to open the chuck.
Place the bur into the chuck and release the button to secure it in position. Ensure that the bur is properly seated to prevent any wobbling during use.
Water Supply:
Connect the handpiece's water supply to the dental unit's water system. Ensure adequate water flow to provide cooling during procedures.
Operation:
Turn on the handpiece following the dental unit's control settings. Monitor the recommended speed and torque for the specific procedure.
Utilize the push-button control to start and stop the handpiece as required.
Post-Operation:
After use, thoroughly clean the handpiece to eliminate any debris or residues. Unplug the handpiece from the dental unit. If needed, take apart the handpiece for more detailed cleaning.
Sterilization:
Autoclave the handpiece along with any removable components at temperatures of up to 135°C.
Keep the sterilized handpiece in a clean and dry place.
Maintenance:
Regularly check the handpiece for signs of wear or damage.
Apply lubricant to the handpiece.
6 MONTHS