MECCO P&C OBTURATION SYSTEMS
  • MECCO P&C OBTURATION SYSTEMS
  • MECCO P&C OBTURATION SYSTEMS
  • MECCO P&C OBTURATION SYSTEMS
  • MECCO P&C OBTURATION SYSTEMS
Product Catalogue
Download Catalogue
 
Shipping Policy
 
Return & Refund Policy
₹11,665.00
₹6,999.00Save 40%
Tax included

P&C IS A DOWNPACK OBTURATION SYSTEM WITH UNIQUE BALL TIP

Quantity
  • The P&C Push & cut 2 in 1Obturation System combines traditional heating pen and lGuttaPercha cutter into one unit.
  • Cut Tip:The innovative and unique ball heating needle enables all the gutta percha to be melted and stuck on the ball nose at one time.
  • Push Tip:Heats and compacts gutta percha vertically before.

MACCO P&C OBTURATION PEN SYSTEM is a Cordless system used for Warm Vertical Compaction while doing Root Canal Treatment.

Using Obturation Pen, one applies pressure in a vertical direction to the heat softened gutta-percha and thereby causes it to flow and to fill the entire lumen of the canal.

It can be heated upto 200° C in 3sec.

INDICATIONS :

  • The obturation pen supports the vertical compaction of gutta-percha for the root canal mainly (the apical parts) filling.
  • It can also be used as a gutta-percha cutter.

ADVANTAGES :

  • Simple design
  • BALL TIP AND Needle type TIP
  • Convenience in application
  • High sealing ability
  • POWER SUPPLY:AC 220 VOLT 50-60 HZ
  • POWER; 10W
No. Accessories Quantities
1 Main unit 1
2 Battery 1
3 Charging base 1
4 Power adapter 1
5 Tips 2
6 Heat insulation sleeve 2
7 Instruction manual 1
8 Certificate of quality 1

HEAT :

  • Press the button to the heat the tip, the LED indicator light Green.
  • The tip can reach a working temperature within 3 seconds.

CHARGE :

  • Put the obturation pen onto the charging base, the LEd indicator light blue. 
  • The unit should be Continuous charged for 12 hours from low voltage to full charge.

MAINTENANCE AND STERILIZATION:

  • Clean and sterilize the pen tip before each treatment.
  • The remaining gutta-percha can be cleaned by a cotton swab.
  • Clean the exterior of the heating unit and charging base by using a soft cloth moistened with a mild detergent or rubbing alcohol.
  • The surface should be sheathed with a plastic barrier to prevent contamination and discoloration.
  • Do not use strong disinfectants or those that contain bleach or ammonium chloride to clean the device.
  • Do not autoclave the heating unit or charging base.
  • After each use, the tips should be sterilized by autoclave for 60 mins at 121 degree Celcius.

NOTE: The temperature of the tip is very high during the surgery, avoid its direct contact to the soft tissue to avoid burns.

6 MONTHS

AVAILABLE OFFERS
QuantityUnit discountYou Save
241%Up to ₹9,565.30
542%Up to ₹24,496.50
Dentalness Benefits
Free Shipping over order of 5000
Free Shipping over order of 5000
Hassle Free Cancellation
Hassle Free Cancellation
10 Days Replacement
10 Days Replacement
100% Genuine Products
100% Genuine Products
Related Products